Anprolene cabinets

Our entry level Anprolene sterilisers are available in 3 sizes to suit your requirements. These sterilisers run at ambient temperature and require minimal installation, just a 2.6cm PVC hose to the outside with the wall plate provided. There are no water or vacuum lines required.

Anprolene sterilisation cycles are designed to be the gentlest available, allowing repeated sterilisation whilst preserving medical devices in pristine condition. An optional abator is available to comply with local requirements on EtO emissions.

Anprolene sterilisers feature include: more powerful ventilation and purge pumps, unique active aeration system, digital display tracks cycle progress, temperature sensor monitors room conditions during each cycle, microprocessor monitors cycle and automatically restores system in case of power failure.

Our range of Anprolene cabinets

Anprolene AN-74i

The standard Anprolene steriliser makes the most economical use of space by fitting across a standard 60cm worktop. This also allows the door to open towards the operator. Any additional aeration required can take place in the steriliser. Cabinet is used with 35l AN-79.16gas kit. The AN-74i steriliser delivers highly effective and safe sterilisation of the widest range of local requirements on EtO emissions.
Go to product description page
Anprolene AN-74ix

The extended Anprolene steriliser allows the operator to sterilise longer medical devices (such as (laparoscopic equipment). It has proven to be particularly popular with equine veterinary practices. Any additional aeration required can take place in the steriliser. Cabinet is used with 35 l AN-79.16 gas kit. AN-74ix steriliser delivers highly effective and safe sterilisation of the widest range of items in a gentle, single process that preserves and extends the life of your products.
GO to product description page
Anprolene AN-74j

The Jumbo is our largest Anprolene cabinet, designed to allow flexible endoscopes to lie flat when they are coiled inside their sterilisation packaging. Any additional aeration required can take place in the steriliser. A popular steriliser with our Equine Vets. The cabinet is all stainless steel. Cabinet is used with 35 l AN-79.16 gas kit.
go to product desctiption page

Comparison Chart

AN-74i AN-74ix AN-74j
Exterior dimensions 53.3 cm (D) x 35.6 cm (W) x 52.1 cm (H) 77.5 cm (D) x 35.6 cm (W) x 52.1 cm (H) 78.7 cm (D) x 45.7 cm (W) x 50.8 cm (H)
Interior dimensions 48.9 cm (D) x 34.5 cm (W) x 32 cm (H) 74 cm (D) x 34.5 cm (W) x 32 cm (H) 74.3 cm (D) x 45.5 cm (W) x 31,8 cm (H)
Cabinet capacity 55 l 84 l 107 l
Chamber (Liner bag) 40 l max 40 l max 40 l max
Net weight 22.9 kg 27.5 kg 38.6 kg
Cycle temperature Room temperature (min 20 °C) Room temperature (min 20 °C) Room temperature (min 20 °C)
Sterilisation cycles 12 hours / 24 hours 12 hours / 24 hours 12 hours / 24 hours
Aeration cycle 2 hours 2 hours 2 hours
Refill kits available AN-79.16
AN-71.00
AN-73.00
AN-79.16
AN-71.00
AN-73.00
AN-79.16
AN-71.00 *
AN-73.00 *
*AN-71 and AN-73 are only compatible with the purchase of a short purge probe

Anprolene Refill kits

AN-79.16

The standard Anprolene refill kit comes with ampoules and liner bags for 14 cycles. Each ampoule contains 17.6 g of EtO and the liner bag (sterilisation chamber) holds up to 35 l.
go to product desctiption page

Accessories/Consumables for Anprolene cabinets

In order to ensure a successful cycle other products may require as below:

Dosimeter

An AN-87 dosimeter should be used in every cycle to confirm that the parameters for sterilisation have been met. The dosimeter measures time, concentration of gas and temperature. Single use item.

go to product desctiption page

Humidichip and humiditube

In order for the cycle to be successful a minimum of 35% humidity is required. Should the humidity be below this a humidichip (Tyvek soaked in sterile water) is placed in a Humiditube, the tube is reusable and is to ensure that the Humidichip is not squashed.

go to product desctiption page

Biological indicators

The “Gold Standard” for ensuring sterilisation has occurred. The Andersen AN-2203 is placed in the centre of the load, at the end of the cycle the inner tube is “snapped” allowing the spore strip in the outer tube to be soaked with the growth medium. The tube is then incubated for 48 hours at 37 °C. If the medium is clear – your load was sterile.

go to product desctiption page

Abator

In certain Countries or Regions local authorities will require an Abator attached to the exhast to reduce any EtO emissions. The abator is easy to install and comes with a cartridge that is good for 200 cycles.

go to product desctiption page