Our entry level Anprolene sterilisers are available in 3 sizes to suit
your requirements. These sterilisers run at ambient temperature and
require minimal installation, just a 2.6cm PVC hose to the outside with
the wall plate provided. There are no water or vacuum lines required.
Anprolene sterilisation cycles are designed to be the gentlest
available, allowing repeated sterilisation whilst preserving medical
devices in pristine condition.
An optional abator is available to comply with local requirements on EtO
emissions.
Anprolene sterilisers feature include: more powerful ventilation and
purge pumps, unique active aeration system, digital display tracks cycle
progress, temperature sensor monitors room conditions during each
cycle, microprocessor monitors cycle and automatically restores system
in case of power failure.
AN-74i | AN-74ix | AN-74j | |
---|---|---|---|
Exterior dimensions | 53.3 cm (D) x 35.6 cm (W) x 52.1 cm (H) | 77.5 cm (D) x 35.6 cm (W) x 52.1 cm (H) | 78.7 cm (D) x 45.7 cm (W) x 50.8 cm (H) |
Interior dimensions | 48.9 cm (D) x 34.5 cm (W) x 32 cm (H) | 74 cm (D) x 34.5 cm (W) x 32 cm (H) | 74.3 cm (D) x 45.5 cm (W) x 31,8 cm (H) |
Cabinet capacity | 55 l | 84 l | 107 l |
Chamber (Liner bag) | 40 l max | 40 l max | 40 l max |
Net weight | 22.9 kg | 27.5 kg | 38.6 kg |
Cycle temperature | Room temperature (min 20 °C) | Room temperature (min 20 °C) | Room temperature (min 20 °C) |
Sterilisation cycles | 12 hours / 24 hours | 12 hours / 24 hours | 12 hours / 24 hours |
Aeration cycle | 2 hours | 2 hours | 2 hours |
Refill kits available | AN-79.16 AN-71.00 AN-73.00 |
AN-79.16 AN-71.00 AN-73.00 |
AN-79.16 AN-71.00 * AN-73.00 * *AN-71 and AN-73 are only compatible with the purchase of a short purge probe |
In order to ensure a successful cycle other products may require as below:
An AN-87 dosimeter should be used in every cycle to confirm that the parameters for sterilisation have been met. The dosimeter measures time, concentration of gas and temperature. Single use item.
go to product desctiption pageIn order for the cycle to be successful a minimum of 35% humidity is required. Should the humidity be below this a humidichip (Tyvek soaked in sterile water) is placed in a Humiditube, the tube is reusable and is to ensure that the Humidichip is not squashed.
go to product desctiption pageThe “Gold Standard” for ensuring sterilisation has occurred. The Andersen AN-2203 is placed in the centre of the load, at the end of the cycle the inner tube is “snapped” allowing the spore strip in the outer tube to be soaked with the growth medium. The tube is then incubated for 48 hours at 37 °C. If the medium is clear – your load was sterile.
go to product desctiption pageIn certain Countries or Regions local authorities will require an Abator attached to the exhast to reduce any EtO emissions. The abator is easy to install and comes with a cartridge that is good for 200 cycles.