Easy Touchscreen
Interactive touchscreen guides user through FDA-cleared instructions for use -
reducing the risk of user error.
After selecting desired exposure and aeration, sterilizer displays exact time the
cycle will complete. Sterilization status and cabinet temperature shown throughout
the cycle.
Built in Quality Check of components is part of standard equipment operation.
Sterilizer automatically performs verification testing before each use.
17.6g EO Cartridge
Terminal sterility with 90% less EO than any other system on the market. Cartridge
protects the hermetically sealed glass EO ampoule from accidental activation.
Process Challenge Device
Built into the purge probe handle to ensure the 10-6
biological indicator is consistently placed in the most difficult location for EO to
reach in every cycle - providing data driven results, regardless of the operator.
12 Hour Exposure Cycle
Achieves FDA-required 10-6 sterility assurance level for terminal
sterilization of medical devices.
Easy Installation
Requires only a 120v or 240v outlet and a 1" dedicated exhaust line.
Free Operator Training
It's like having a sterilization expert on staff! Free operator training for the life
of your sterilizer and free 24/7 support.
Smart Cabinet Design
An interior ventilation port in the back of the chamber actively draws fresh air from
the room throughout the entire cycle. Ensuring air flow in one direction and
minimizing potential operator exposure.
Active Aeration in Same Chamber
Andersen's purge probe flushes the liner bag with a constant flow of fresh air at the
end of the cycle - no need to transfer items to a separate area. Two hours of
aeration standard. EO-absorbent items may require additional aeration. Active
aeration continues indefinitely until products are removed.
35L Sterilization Bag
Made of gas impermeable materials to maintain consistent gas concentration throughout
the cycle. Liner bag cleared for up to 24 lb.
Make Your System Zero Emissions
Andersen abators are a simple, cartridge-based system that employ a dry catalyst
resin. The resin converts ethylene oxide to biodegradable organic compounds.
Replaceable abator cartridge has a 200 cycle capacity. Spent cartridges are
non-hazardous.
Unmatched Sterilization
compatibility
Anprolene's 100% EO system sterilizes at room temperature without external vacuum
lines or steam generator. Protects your most delicate instruments, electronics,
drills, fiber optics, hand pieces and cameras. As well as those plastic, fabric,
cellulose or rubber items that you can't sterilize with other methods. Most any item
with the exception of food, drugs or liquids can be sterilized.
Shelf Life
The FDA has cleared AN75 sterilization loads wrapped with Tyvek Sterilization
Pouches with Chevron Seal or Sterisheet - both have a shelf life of at least three
months.